百检网首页 我的订单 400-101-7153

SAE J 2517-2010 混合动力III系箱形电位器校准规程

作者:百检网 时间:2021-07-15

标准号:SAE J 2517-2010
中文标准名称:混合动力III系箱形电位器校准规程
英文标准名称:Hybrid III Family Chest Potentiometer Calibration Procedure
标准类型:R16
发布日期:2010/9/28 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:R16
国际标准分类号:43.180
引用标准:SAE J 211/1-2007;SAE J 2570-2009;SAE J 2706-2007;SAE J 2856-2009;SAE J 2857;SAE Engineering Aid 25;SAE Engineering Aid 26;FMVSS No.572
适用范围:This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent nonlinearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is non-linear. Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/ (volt/volt) or mm/ (mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the non- linearity and others did not. Of those that did correct for the non-linearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Subcommittee (DTES), and led to overall variability in chest compression measurements between laboratories. The intent of this recommended practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin to test this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The initial version of J2517 released in May 2000 attempted to fix this problem by recommending a two-point calibration which was not intended to correct for the nonlinearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also did not require the measurement of a starting position of the potentiometer before each crash test, thus it did not correct for the difference in starting chest geometry between a subject dummy and its design intent. It was intended to be a simple and reproducible calibration procedure which crash test facilities could easily adopt with little or no modifications to their facilities. In practice, most laboratories did not adopt the procedure since it did not correct for the nonlinearities. Recent attempts to reduce dummy to dummy and lab to lab variations at lower deflection levels (around 25 mm) have renewed interest in adopting a calibration procedure to correct for the nonlinearity of the measurement system. This current revision of this procedure uses a multipoint calibration with a third order regression to correct for the nonlinearities of the system with a standardized method. It requires changes in the calibration method of the transducer, the datacollection procedures when used in a dummy, and the processing procedures after test data is collected. Following this standardized methodology will minimize linearity errors as well as lab to lab variations.

相关标准

《GB/T 5585.2-2018》电工用铜、铝及其合金母线 第2部分:铝和铝合金母线 GB/T 5585.2-2018
《GB/T 28427-2012》电气化铁路27.5kV单相交流交联聚乙烯绝缘电缆及附件 GB/T 28427-2012
《GB/T 28427-2012》电气化铁路27.5kV单相交流交联聚乙烯绝缘电缆及附件 GB/T 28427-2012
《GB/T 17650.2-1998 IEC 60754-2:1991》取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度 GB/T 17650.2-1998 IEC 60754-2:1991 6,7
《GB/T 3048.12-2007 IEC 60885-3:1988》电线电缆电性能试验方法 第12部分: 局部放电试验 GB/T 3048.12-2007 IEC 60885-3:1988 5,6
《GB/T 1040.1-2018 ISO 527-1:2012》塑料 拉伸性能的测定 第1部分:总则 GB/T 1040.1-2018 ISO 527-1:2012
《GB/T 18380.34-2008 IEC 60332-3-23:2000》电缆和光缆在火焰条件下的燃烧试验 第34部分:垂直安装的成束电线电缆火焰垂直蔓延试验 B类 GB/T 18380.34-2008 IEC 60332-3-23:2000
《GB/T 18380.35-2008 IEC 60332-3-24:2000》电缆和光缆在火焰条件下的燃烧试验 第35部分:垂直安装的成束电线电缆火焰垂直蔓延试验 C类 GB/T 18380.35-2008 IEC 60332-3-24:2000
《GB/T 2951.12-2008 IEC 60811-1-2:1985》电缆和光缆绝缘和护套材料通用试验方法 第12部分:通用试验方法 热老化试验方法 GB/T 2951.12-2008 IEC 60811-1-2:1985
《GB/T 3682.1-2018 ISO 1133-1:2011》塑料 热塑性塑料熔体质量流动速率(MFR)和熔体体积流动速率(MVR)的测定 第1部分:标准方法 GB/T 3682.1-2018 ISO 1133-1:2011
百检网专注于为第三方检测机构以及中小微企业搭建互联网+检测电商服务平台,是一个创新模式的检验检测服务网站。百检网致力于为企业提供便捷、高效的检测服务,简化检测流程,提升检测服务效率,利用互联网+检测电商,为客户提供多样化选择,从根本上降低检测成本提升时间效率,打破行业壁垒,打造出行业创新的检测平台。

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 桑德斯微电子器件(南京)有限公司
  • 上海嘉叠贸易有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
  • 宁波图米文具用品有限公司
  • 江苏力之创特种装备制造有限公司

相关资讯

暂无相关资讯
百检网