百检网首页 我的订单 400-101-7153

ISO 11843-5-2008 检测能力.第5部分:线性和非线性校准容器中的方法学

作者:百检网 时间:2021-07-31

标准号:ISO 11843-5-2008
中文标准名称:检测能力.第5部分:线性和非线性校准容器中的方法学
英文标准名称:Capability of detection - Part 5: Methodology in the linear and non-linear calibration cases
标准类型:N04
发布日期:1999/12/31 12:00:00
实施日期:1999/12/31 12:00:00
中国标准分类号:N04
国际标准分类号:03.120.30;17.020
引用标准:ISO 3534-1;ISO 3534-2;ISO 3534-3;ISO 5725-1;ISO 11843-1-1997;ISO 11843-2-2000
适用范围:This part of ISO 11843 is concerned with calibration functions that are either linear or non-linear.It specifies basic methods to-- construct a precision profile for the response variable, namely a description of the standard deviation (SD) or coefficient of variation (CV) of the response variable as a function of the net state variable,-- transform this precision profile into a precision profile for the net state variable in conjunction with the calibration function, and-- use the latter precision profile to estimate the critical value and minimum detectable value of the net state variable.The methods described in this part of ISO 11843 are useful for checking the detection of a certain substanceby various types of measurement equipment to which ISO 11843-2 cannot be applied. Included are assays ofpersistent organic pollutants (POPs) in the environment, such as dioxins, pesticides and hormone-likechemicals, by competitive ELISA (enzyme-linked immunosorbent assay), and tests of bacterial endotoxinsthat induce hyperthermia in humans.The definition and applicability of the critical value and minimum detectable value of the net state variable aredescribed in ISO 11843-1 and ISO 11843-2. This part of ISO 11843 extends the concepts in ISO 11843-2 tothe cases of non-linear calibration.The critical value, Xc, and minimum detectable value, xd, are both given in the units of the net state variable. Ifxc and xd are defined based on the distribution for the response variable, the definition should include thecalibration function to transform the response variable to the net state variable. This part of ISO 11843 definesxc and xd based on the distribution for the net state variable independently of the form of the calibrationfunction. Consequently, the definition is available irrespective of the form of this function, whether it is linear ornon-linear.The calibration function should be continuous, differentiable, and monotonically increasing or decreasing.A further method is described for the cases where the SD or CV is known only in the neighbourhood of theminimum detectable value.Examples are provided.

相关标准

《GB/T26384-20115.2.8》针织棉服装
《GB/T31888-20155.6》中小学生校服
《GB/T31888-20155.3》中小学生校服
《GB/T31888-20155.2》中小学生校服
《GB/T33271-20164.13》机织婴幼儿服装
《GB/T31900-20154.4.1》机织儿童服装
《GB/T31900-20153.12.1》机织儿童服装
《GB/T22848-20096.5》针织成品布
《GB/T31888-20155.4》中小学生校服
《GB/T31900-20153.12.1》机织儿童服装
百检网专注于为第三方检测机构以及中小微企业搭建互联网+检测电商服务平台,是一个创新模式的检验检测服务网站。百检网致力于为企业提供便捷、高效的检测服务,简化检测流程,提升检测服务效率,利用互联网+检测电商,为客户提供多样化选择,从根本上降低检测成本提升时间效率,打破行业壁垒,打造出行业创新的检测平台。

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 桑德斯微电子器件(南京)有限公司
  • 上海嘉叠贸易有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
  • 宁波图米文具用品有限公司
  • 江苏力之创特种装备制造有限公司

相关资讯

暂无相关资讯

最新资讯

百检网