百检网首页 我的订单 400-101-7153

BS EN 61558-2-6-2009 小于1100V供电电压用变压器、电抗器、供电机组及类似设备的安全性.安全隔离变压器及含有安全隔离变压器的供电机组用试验及详细要求

作者:百检网 时间:2021-08-04

标准号:BS EN 61558-2-6-2009
中文标准名称:小于1100V供电电压用变压器、电抗器、供电机组及类似设备的安全性.安全隔离变压器及含有安全隔离变压器的供电机组用试验及详细要求
英文标准名称:Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V. Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
标准类型:K41
发布日期:2010/1/31 12:00:00
实施日期:2010/1/31 12:00:00
中国标准分类号:K41
国际标准分类号:29.180
引用标准:IEC 61558-1-2005
适用范围:Replacement:This part of IEC 61558 deals with the safety of safety isolating transformers for generalapplications and power supply units incorporating safety isolating transformers for general applications. Transformers incorporating electronic circuits are also covered by this standard.NOTE 1 Safety includes electrical, thermal and mechanical aspects.Unless otherwise specified, from here onward, the term transformer covers safety isolating transformers for general applications and power supply units incorporating safety isolating transformers for general applications.NOTE 2 For power supply units (linear) this part is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this part.This part is applicable to stationary or portable, single-phase or polyphase, air-cooled(natural or forced) independent or associated dry- type transformers. The windings may beencapsulated or non-encapsulated.The rated supply voltage does not exceed 1 100 V a.c., and the rated supply frequencyand the internal operating frequencies do not exceed 500 Hz.The rated output does not exceed:– 10 kVA for single-phase transformers;– 16 kVA for polyphase transformers.This part is applicable to transformers without limitation of the rated output subject to anagreement between the purchaser and the manufacturer.NOTE 3 Transformers intended to supply distribution networks are not included in the scope.The no-load output voltage or the rated output voltage does not exceed 50 V a.c. or 120 Vripple-free d.c.This part is not applicable to external circuits and their components intended to be connectedto the input terminals and output terminals of the transformers.Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard.

相关标准

《GB 20840.3-2013》互感器 第3部分:电磁式电压互感器的补充技术要求 GB 20840.3-2013 7.3.2
《GB 20840.3-2013》互感器 第3部分:电磁式电压互感器的补充技术要求 GB 20840.3-2013 7.3.7
《DL/T698.35-2010》电能信息采集与管理系统 第3-5部分:电能信息采集终端技术规范低压集中抄表终端特殊要求 DL/T698.35-2010 4.3.2
《DL/T698.35-2010》电能信息采集与管理系统 第3-5部分:电能信息采集终端技术规范低压集中抄表终端特殊要求 DL/T698.35-2010 4.5
《DL/T698.35-2010》电能信息采集与管理系统 第3-5部分:电能信息采集终端技术规范低压集中抄表终端特殊要求 DL/T698.35-2010 4.3.3
《GB/T11150-2001》电能表检验装置 GB/T11150-2001 5.1
《GB/T11150-2001》电能表检验装置 GB/T11150-2001 5.8表3中序号13
《GB/T11150-2001》电能表检验装置 GB/T11150-2001 5.7
《GB/T11150-2001》电能表检验装置 GB/T11150-2001 5.11
《GB/T11150-2001》电能表检验装置 GB/T11150-2001 5.8表3中序号3
百检网专注于为第三方检测机构以及中小微企业搭建互联网+检测电商服务平台,是一个创新模式的检验检测服务网站。百检网致力于为企业提供便捷、高效的检测服务,简化检测流程,提升检测服务效率,利用互联网+检测电商,为客户提供多样化选择,从根本上降低检测成本提升时间效率,打破行业壁垒,打造出行业创新的检测平台。

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 桑德斯微电子器件(南京)有限公司
  • 上海嘉叠贸易有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
  • 宁波图米文具用品有限公司
  • 江苏力之创特种装备制造有限公司

相关商品

暂无相关商品

相关资讯

暂无相关资讯
百检网