BS EN 60664-5-2007 低压系统内设备的绝缘配合.间隙距离和漏电距离小于或等于2mm的测定用综合方法

作者:百检网 时间:2021-07-20

标准号:BS EN 60664-5-2007
中文标准名称:低压系统内设备的绝缘配合.间隙距离和漏电距离小于或等于2mm的测定用综合方法
英文标准名称:Insulation coordination for equipment within low-voltage systems - Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
标准类型:K31
发布日期:2007/12/31 12:00:00
实施日期:2007/12/31 12:00:00
中国标准分类号:K31
国际标准分类号:29.080.30
引用标准:IEC 60364-5-51-2005;IEC 60664-1-2007;IEC 60721-3-3-1994;IEC 60721-3-7-1995;IEC 60721-3-9-1993
适用范围:This part of IEC 60664 specifies the dimensioning of clearances and creepage distances forspacings equal to or less than 2 mm for printed wiring board and equivalent constructions,where the clearance and the creepage distance are identical and are along the surface of solidinsulation, such as the paths described in 6.2 of Part 12 (Examples 1, 5 and 11).The dimensioning in this standard is more precise than that provided by Part 1. However, if theprecision provided by this standard is not required, Part 1 may be applied instead.This standard can only be used in its entirety. It is not permitted to select one or more clausesfrom this standard and to use them in place of the corresponding clauses of Part 1. In addition,this part of IEC 60664 can only be used together with Part 1.When this Part 5 is applied to the dimensioning of clearances and creepage distances equal toor less than 2 mm, all clauses are used in place of the corresponding clauses given in Part 1.For clearances and creepage distances larger than 2 mm, and for solid insulation in general,Part 1 applies.NOTE 1 The limitation to distances equal to or less than 2 mm applies to basic or supplementary insulation. Thetotal distance of a reinforced or double insulation may be larger than 2 mm.This standard is based on the following criteria for dimensioning:– minimum clearances independent of the micro-environment (see Table 2);– minimum creepage distances for pollution degrees 1, 2 and 3 to avoid failure due totracking (see Table 4);– minimum creepage distances to avoid flashover across the insulating surface (seeTable 5).NOTE 2 For minimum creepage distances to maintain adequate insulation resistance, see Table A.2.NOTE 3 This standard is not applicable to micro-environmental conditions worse than pollution degree 3 orhumidity level 3.A test method is specified for allocating unclassified insulating material to the relevant wateradsorption group.

相关标准

百检网专注于为第三方检测机构以及中小微企业搭建互联网+检测电商服务平台,是一个创新模式的检验检测服务网站。百检网致力于为企业提供便捷、高效的检测服务,简化检测流程,提升检测服务效率,利用互联网+检测电商,为客户提供多样化选择,从根本上降低检测成本提升时间效率,打破行业壁垒,打造出行业创新的检测平台。

百检能给您带来哪些改变?

1、检测行业全覆盖,满足不同的检测;

2、实验室全覆盖,就近分配本地化检测;

3、工程师一对一服务,让检测更精准;

4、免费初检,初检不收取检测费用;

5、自助下单 快递免费上门取样;

6、周期短,费用低,服务周到;

7、拥有CMA、CNAS、CAL等权威资质;

8、检测报告权威有效、中国通用;

客户案例展示

  • 上海朗波王服饰有限公司
  • 浙江圣达生物药业股份有限公司
  • 天津市长庆电子科技有限公司
  • 桑德斯微电子器件(南京)有限公司
  • 上海嘉叠贸易有限公司
  • 上海纽特丝纺织品有限公司
  • 无锡露米娅纺织有限公司
  • 东方电气风电(凉山)有限公司
  • 宁波图米文具用品有限公司
  • 江苏力之创特种装备制造有限公司

相关资讯

暂无相关资讯
百检网